Control terminals
Important notes

5

l

90

EDKVF9338 DE/EN/FR 4.0

5.5

Control terminals

5.5.1

Important notes

(

Stop!

The control card will be damaged if

ƒ

the voltage between X5/39 and PE or X6/7 and PE is greater than 50 V,

ƒ

the voltage between voltage source and X6/7 exceeds 10 V (common mode)
in case of supply via external voltage source.

Limit the voltage before switching on the drive controller:

ƒ

Connect X5/39, X6/2, X6/4 and X6/7 directly to PE or

ƒ

use voltage−limiting components.

ƒ

For trouble−free operation, the control cables must be shielded:
– Connect the shield of digital input and output cables at both ends.
– Connect the shield of analog input and output cables at one end (at the drive

controller).

– For lengths of 200 mm and more, use only shielded cables for analog and digital

inputs and outputs. Under 200 mm, unshielded but twisted cables may be used.