Machine constants, List of machine constants – Lenze ETC Motion Control User Manual
Page 231

Machine constants
List of machine constants
4.16
l
231
EDSTCXN EN 2.0
1234,
/* input number of the neg. limit switch */
1234;
/* input number of the pos. limit switch */
MK_US
0,
/* monitor. of the position encoder protection signal */
0,
/* 1 = monitoring active, 0 = inactive */
0,
0,
0,
0;
MK_UA0
0,
/* cable breakage monitoring, position encoder zero pulse */
0,
/* 1 = monitoring active, 0 = inactive */
0,
0,
0,
0;
MK_UA12
0,
/* cable breakage monitoring, position encoder signal Ua1/Ua2
*/
0,
/* 1 = monitoring active, 0 = inactive */
0,
/* 2 = ignore nonrecurring fault */
0,
0,
0;
MK_TEACHACHSE
1,
/* marking of axes that are to be */
1,
/* transferred via the teach−in box */
1,
/* during teaching */
0,
0,
0;
MK_MASSSTAB
1,
/* multiplication factor for the position */
1,
/* programmed in a DIN block */
1,
1,
1,
1;
MK_HANDRADZUORDNUNG
0,
/* assignment of axes to handwheels */
0,
/* 0 = handwheel 0, 1 = handwheel 1 */
0,
0,
0,
0;
MK_HANDRADFAKTOR
1,
/* individual evaluation factor for the */
1,
/* handwheel funct., e.g. for special treatment */
1,
/* of rotation axes */
1,
1,
1;