Etc−mmi−gateway – Lenze ETC Motion Control User Manual
Page 280

ETC−MMI−Gateway
Configuring the ETC−MMI gateway
Connection − Setting up connections
6.3
6.3.1
l
280
EDSTCXN EN 2.0
If you want to display the communication status of the selected connection,
click the Details button.
ETCN060
Via the Settings button, you can edit the communication parameters of the
selected connection if e.g. the IP address of the control system has changed.
ETCN004
Name and Control cannot be changed. If you also want to change the control
type, delete a connection and create a new connection with the same name.
IP address: Specify the communication parameters that depend on the
control type:
ƒ ETCHC = IP address (
¶ 28)
ƒ ETCPC = Index of the PCI cards (indexes of the PCI cards are in the range
0 ... 9 and are automatically assigned by the driver. The first ETCPC has
the index 0).
<Ok>: Use this button to write entries in the file "mmigtway.ini" (
¶ 283). If
a connection with the same parameters already exists, the error "Gateway
cannot change the parameter" is reported.
New parameters are adopted immediately by the gateway.
Details – Display
communication status
Settings – Edit connection
parameters