Interface PLC <˘> NC operating system

Extended interface for MMI functions

Data block 15

5

5.2

5.2.2

l

275

EDSTCXN EN 2.0

Data word

Name

Direction

Type of signal

036

General override for axes

HMI

→

NC

static

037

Override for spindle speeds

HMI

→

NC

static

038

Override for oscillation speed

HMI

→

NC

static

039

Override for PLC axes (Target
position approach)

HMI

→

NC

static

Definition of a signed evaluation factor for the currently valid traversing
speed. The specification is made in steps of 0.1 %.

Effect in the NC: The selected value is used as factor for evaluating the cur-
rently programmed maximum speed by the rough interpolator.

The override is effective in both manual as well as automatic operation. It
can be inhibited within a program via M functions.

Data word

Name

Direction

Type of signal

040−043

Speed preselection for traverse keys

HMI

→

NC

static

Definition of speed during modal traveling using the traverse keys. Specifi-
cation in [mm/min] as 64−bit floating point number.

Effect in the NC: The selected value is accepted at a fixed position in the para-
meter field. Every time the traverse key is actuated, the respective axis is mo-
ved modally at the speed entered.

Data word

Name

Direction

Type of signal

044−047

Increment preselection

HMI

→

NC

static

Definition of increment during manual traversing in inching mode. Specifi-
cation in [mm] or [inch] as 64−Bit floating point number.

Effect in the NC: The selected value is accepted at a fixed position in the para-
meter field. Every time the traverse key is actuated, the respective axis is mo-
ved about the delta specified.