MTS Criterion™ Series 60 Product Manual

18

Description

Introduction

Integrated Operations

Platform

The Integrated Operations Platform is comprised of an electromotor, oil pump,
oil reservoir, air cooler, servovalve, other controlling valves, integrating
manifolds, a temperature sensor, and other hydraulic components. The
servovalve, transducers, controller, and the testing software form a closed-loop
control system. Hydraulic oil temperature is kept at its setting range by an air
cooler. Under normal operating conditions, the temperature should be lower than
60°C (140°F), and its highest temperature cannot exceed 65°C (149°F). If the oil
temperature is higher than 65°C (149°F), turn off the machine and contact MTS.

Internal to the Integrated Operations Platform is an outlet switch for the
computer and monitor.

Plugging in a device could damage the device or the the Integrated
Operations Platform.

The user should not plug in any device to this outlet switch without consulting
MTS.