Specifications – integrated operations platform, Specifications – integrated operations platform 24 – MTS Criterion 60 - Manual User Manual
Page 24
MTS Criterion™ Series 60 Product Manual
24
Specifications
Introduction
Specifications – Integrated Operations Platform
The following integrated operations platform specifications are common for
models of 64.305/64.305E, 64.605/64.605E, and 64.106/64.106E.
Integrated Operations Platform Specifications
P
ARAMETER
S
PECIFICATION
Calibration standard
ISO 7500 Class 1 or ASTM E4
Force range
1%-100% of rated force capacity
Force indicating accuracy
± 1% of indicating
Position resolution
0.2 μm
(0.00000787 in)
Position accuracy
+/- 1% of indicating
Strain accuracy
ASTM E83 or ISO 8513
Security protection
over-force, travel limits, over-pressure, over-
temperature, over-current and others
Over force protection
10%
Data acquisition rate
1000 Hz maximum
Control loop rate
1000 Hz
Environmental requirements
Operating temperature range
5-40°C (41-104°F)
Operating humidity
5-85% noncondensing
Storage temperature range
18-49°C (0 -120°F)
Maximum storage humidity
90% noncondensing
Maximum altitude
2000 m (6500 ft)
Integrated Operations Platform power
requirements
3~3W+PE
400 V 50 Hz / 480 V 60Hz
Integrated Operations Platform dimensions
Height
1900 mm
(74.80 in)
Width
1040 mm
(40.94 in)