Decommissioning

7. Dispose of all hydraulic fluid in accordance with all local codes regarding

hazardous materials handling and disposal.

Customer should follow internal safety policies for safe disposal of parts of
the machine. Refer to MSDS for oils and greases that are used on the
machine.

Before power is turned off, the cables carry electrical current.

Removing the crosshead motor cables without turning off the power can
cause personnel injury or death.

Ensure that the main power is off and the Electrical Disconnect is locked out
before you remove the crosshead motor cable.

Remove the cables from the safety enclosure wiring slots carefully when removing
the operation box cable if you have a safety enclosure installed for your system.

8. Remove all cables on the load frame.

Remove cables on the crosshead motor. Remove D-connectors for sensors and
limit switches on the boardings along with the cables. Remove the D-connector
and its cable on the handset and take the handset off. Open the lower part of the
operation box and remove the handset connection cable.

9. If you have a safety enclosure installed for your system, remove it according

to

“Installing the Optional Safety Enclosure”

on page 59.

10. Remove the load frame anchor bolts.

11. Move the load frame and Integrated Operations Platform to the desired

position according to the Lifting and Moving Instructions.

Electrical components and parts can contain hazardous chemicals and
compounds.

Customer should follow internal safety policies for safe disposal of parts of
the machine. Refer to MSDS for oils and greases that are used on the
machine.

Always refer to local codes that govern the disposal of potentially hazardous
materials and follow these codes for the proper handling and disposal of these
materials.