Analog outputs setup – SATEC RDM172 Manual User Manual

Page 50

Advertising
background image

Chapter 3 Display Operations

Menu Operations

50

Series PM172 Powermeters

To change the analog input options:

1. Use the UP and DOWN arrow buttons to scroll to the desired

parameter.

2. Press the SELECT button to activate the lower window.
3. Use the UP and DOWN arrow buttons to adjust the parameter

value.

4. Press ENTER to confirm the new parameter setting, or press

ESC to discard changes.

5. You are returned to the middle window to select another

parameter, or store your new settings and exit the menu.

To store new settings and exit the menu:
1. When the middle window is highlighted, press the ENTER button.
2. You return to the main menu.

To exit the menu without saving your changes, press ESC.

The following table lists available analog input options.

Label Parameter Options

Description

Lo Zero

scale 0-999,999

The low engineering scale (in
primary units) for the analog input

corresponding to a lowest (zero)
input current (0 or 4 mA)

Hi Full

scale

0-999,999

The high engineering scale (in
primary units) for the analog input
corresponding to a highest input
current (1 or 20 mA)

dEc.P Number

of

decimal places

0-3

The number of decimal digits in a
fractional part of the scaled

engineering value

Analog Outputs Setup

This entry appears only if the meter is ordered with optional analog outputs.
For more information on configuring analog inputs in your meter, see
“Programming Analog Outputs” in Chapter 4.

To enter the menu, select the “A.Ou.1” or “A.Ou.2” entry from the main menu
for the AO1 and AO2 output respectively, and then press the ENTER button.

To change the analog output options:

1. Use the UP and DOWN arrow buttons to scroll to the desired

parameter.

2. Press the SELECT button to activate the lower window.
3. Use the UP and DOWN arrow buttons to adjust the parameter

value.

4. Press ENTER to confirm your new parameter setting, or press

ESC to discard changes.

5. You are returned to the middle window to select another

parameter, or store your new settings and exit the menu.

To store new settings and exit the menu:
1. When the middle window is highlighted, press the ENTER button.
2. You return to the main menu.

To exit the menu without saving your changes, press ESC.

The following table lists available analog output options. For a list of the
available output parameters and their scales, see “Programming Analog

Outputs” in Chapter 4.

A.In.1

ESC

A.In.1

0

Lo

A.In.1

230

Hi

A.In.1

1

dEc.P

A.Ou.1

ESC

A.Ou.1

rt.U1

OutP

A.Ou.1

0

Lo

A.Ou.1

230

Hi