Do not remove mov, Mov input filter cap cm cap, Input filter cap – Rockwell Automation 20D PowerFlex 700S Phase II Drive Frames 1...6 Installation Instructions User Manual

Page 32: Mov cm cap

Advertising
background image

32

Rockwell Automation Publication 20D-IN024C-EN-P - July 2013

PowerFlex 700S Adjustable Frequency AC Drive - Phase II Control

Fr

am

e

Vo

lt

ag

e

Co

de

Current

Ra

ti

ng

Factory Default Jumper Settings

Power Source Type

MOV/Input Filter
Caps

(1) (2)

DC Bus Common
Mode Caps

6

B
C
D
H
J
N
P
R

All

Two green/yellow
wires connected to
Power Terminal
Block “PE”

Green/yellow wire to
CM Cap Board is
connected to Power
Terminal Block “PE”

Solid Ground
1. The green/yellow CM Cap jumper wire should

be connected to “PE.”

2. The MOV/Input Filter Cap jumper wires should

be connected to “PE.”

Non-Solid Ground
1. The green/yellow CM Cap jumper wire should

be insulated from ground. If necessary, remove
the jumper wire from “PE” and insulate/secure
it to guard against unintentional contact with
chassis or components. Important: Do Not
Remove/Disconnect the larger green/
yellow wire
.

2. MOV/Input Filter Cap jumper wires should be

insulated from ground. If necessary, remove
the jumper wires from “PE” and individually
insulate/ secure each jumper wire to guard
against unintentional contact with chassis or
components.

E
F
T
W

All

Two green/yellow
wires connected to
Power Terminal
Block “PE” and
chassis

Green/yellow wire to
CM Cap Board is
connected to Power
Terminal Block “PE”

Solid Ground
1. The green/yellow CM Cap and MOV jumper

wires should be connected to “PE.”

2. The Input Filter Cap jumper wire (top right)

should be connected to chassis ground with a
metal screw. Verify. If necessary, remove the
nylon screw/spacer and insert a metal M5 x 10
screw. Torque to 3.2 N•m (28 lb•in).

Non-Solid Ground
1. The green/yellow CM Cap and MOV jumper

wires should be insulated from ground. If
necessary, remove them from “PE” and
individually insulate/secure each jumper wire
to guard against unintentional contact with
chassis or components. Important: Do Not
Remove/Disconnect the larger green/
yellow wire
.

2. The Input Filter Cap jumper wire (top right)

should be insulated from ground with a nylon
screw/spacer. Verify. If necessary, remove the
metal screw and insert a M5 x 15 nylon screw/
spacer.

(1) AC input drives only. MOV’s and input filter caps do not exist on DC input drives.
(2) When removing MOV’s, the input filter capacitor must also be removed.

DC–

DC+

BR1

BR2

USE 75 C COPPER WIRE ONLY, TORQUE 52 IN-LB (6 N-M)

22-10
AWG

5.3 IN-LB
(0.6 N-M)

WIRE STRIP

PS+

PS–

USE 75 C

COPPER WIRE

ONLY

TORQUE
52 IN-LB

(6 N-M)

U

T1

V

T2

W

T3

R

L1

S

L2

INPUT

OUTPUT

T

L3

PE

PE

Optional

Communications

Module

PE

PE

MOV

Input Filter Cap

CM Cap

DO NOT
REMOVE

MOV

DC–

DC+

BR1

BR2

USE 75 C COPPER WIRE ONLY, TORQUE 52 IN-LB (6 N-M)

22-10
AWG

5.3 IN-LB
(0.6 N-M)

WIRE STRIP

PS+

PS–

USE 75 C

COPPER WIRE

ONLY

TORQUE
52 IN-LB

(6 N-M)

U

T1

V

T2

W

T3

R

L1

S

L2

INPUT

OUTPUT

T

L3

PE

PE

Optional

Communications

Module

Input Filter Cap

PE

PE

MOV

CM Cap

DO NOT
REMOVE

MOV

Advertising
This manual is related to the following products: