Wiring the Stegmann Hi-Resolution Feedback Option Card to an Encoder

Terminal block P1 contains connection points for a Stegmann Hiperface®
encoder. This terminal block resides on the Hi-Resolution Encoder Feedback
Option card.

Stegmann Hi-Resolution Encoder Option Terminal Designations

TIP

Remember to route wires through the sliding access panel at the bottom of the
control assembly.

Terminal

Signal

Description

12

POWER COMMON

Power supply for encoder interface.

11

POWER

10

REFSIN

Negative Sine signal.

9

+SIN

Positive Sine signal.

8

REFCOS

Negative Cosine signal.

7

+COS

Positive Cosine signal.

6

SHIELD

Connection point for encoder cable
shield.

5

SHIELD

4

N/C

Not connected.

3

N/C

2

DATA+ (RS 485)

Positive DH485 terminal.

1

DATA- (RS 485)

Negative DH485 terminal.