Primary Encoder Interface
Supports 5V DC or 12V DC differential encoders
with internal power supply.
Used as primary closed loop feedback.

Internal Supply

Using Encoder 0 as speed feedback:
Par 222 [Mtr Fdbk Sel Pri] = 0 “Encoder 0” (default)
Par 232 [Encoder0 PPR] = Pulses/Rev for installed encoder

External Supply

Input/Output

Connection Example

Required Parameter Changes

A-

A

Encoder

13

14

15

16

17

18

19

20

21

22

23

24

B-

B

Z-

Z

-

+

Power +V

Common -V

Shield

A-

A

Encoder

13

14

15

16

17

18

19

20

21

22

23

24

B-

B

Z-

Z

-

+