Table 1 – Rockwell Automation 20-750-PBUS Profibus DPV1 Option Module User Manual
Page 21

Rockwell Automation Publication 750COM-UM004B-EN-P - September 2012
21
Installing the Option Module Chapter 2
Table 1 - Node Address Switch Settings
Descriptions of node address values are as follows.
The switch settings can be verified by viewing
Device Parameter 06 - [Net Addr
Act]
, a read-only parameter, with any of the following drive configuration tools:
• PowerFlex 20-HIM-A6 or 20-HIM-C6S HIM
• Connected Components Workbench software, version 1.02 or later
• DriveExplorer software, version 6.01 or later
• DriveExecutive software, version 5.01 or later
Node
Address
Node Address Switch
Node
Address
Node Address Switch
7
6
5
4
3
2
1
7
6
5
4
3
2
1
00
0
0
0
0
0
0
0
14
0
0
0
1
1
1
0
01
0
0
0
0
0
0
1
15
0
0
0
1
1
1
1
02
0
0
0
0
0
1
0
16
0
0
1
0
0
0
0
03
0
0
0
0
0
1
1
17
0
0
1
0
0
0
1
04
0
0
0
0
1
0
0
18
0
0
1
0
0
1
0
05
0
0
0
0
1
0
1
19
0
0
1
0
0
1
1
06
0
0
0
0
1
1
0
20
0
0
1
0
1
0
0
07
0
0
0
0
1
1
1
…
08
0
0
0
1
0
0
0
120
1
1
1
1
0
0
0
09
0
0
0
1
0
0
1
121
1
1
1
1
0
0
1
10
0
0
0
1
0
1
0
122
1
1
1
1
0
1
0
11
0
0
0
1
0
1
1
123
1
1
1
1
0
1
1
12
0
0
0
1
1
0
0
124
1
1
1
1
1
0
0
13
0
0
0
1
1
0
1
125
1
1
1
1
1
0
1
Node Address Value
Description
00
If the Node Address value is set to ‘00’, the option module uses Device
Parameter 05 - [Net Addr Cfg] to set the Node Address. See
.
01…125
Node address used by the option module.
126
The default address setting.