Installing the Adapter

Chapter 2

Node Address Switch Settings

Description of Node Address Switches

The switch settings can be verified by viewing the

Device parameter 06 [Net

Addr Act]

, a read-only parameter, with any of the following drive configuration

tools:

PowerFlex 520-series drive built-in keypad

PowerFlex 22-HIM-A3 or 22-HIM-C2S HIM

Connected Components Workbench software (version 3 or greater)

Connecting the Adapter to
the Drive

1.

Remove power from the drive.

2.

Use static control precautions.

3.

Separate the drive’s control module from the power module.

Node
Address

Node Address Switch

Node
Address

Node Address Switch

7

6

5

4

3

2

1

7

6

5

4

3

2

1

00

0

0

0

0

0

0

0

15

0

0

0

1

1

1

1

01

0

0

0

0

0

0

1

16

0

0

1

0

0

0

0

02

0

0

0

0

0

1

0

17

0

0

1

0

0

0

1

03

0

0

0

0

0

1

1

18

0

0

1

0

0

1

0

04

0

0

0

0

1

0

0

19

1

0

1

0

0

1

1

05

0

0

0

0

1

0

1

20

0

0

1

0

1

0

0

06

0

0

0

0

1

1

0

...

07

0

0

0

0

1

1

1

120

1

1

1

1

0

0

0

08

0

0

0

1

0

0

0

121

1

1

1

1

0

0

1

09

0

0

0

1

0

0

1

123

1

1

1

1

0

1

0

10

0

0

0

1

0

1

0

124

1

1

1

1

0

1

1

11

0

0

0

1

0

1

1

125

1

1

1

1

1

0

0

12

0

0

0

1

1

0

0

126

1

1

1

1

1

0

1

13

0

0

0

1

1

0

1

127

1

1

1

1

1

1

1

14

0

0

0

1

1

1

0

Node Address Value

Description

00 or 127

If the Node Address switches are set to ‘00’ (the default setting) or 127, the adapter uses Device
parameter 05 [Net Addr Cfg] to set the Node Address. See

Setting the Node Address on

page 25

.

01...126

Node Address used by the adapter.

ATTENTION: Risk of injury or death exists. The PowerFlex drive may contain
high voltages that can cause injury or death. Remove power from the drive, and
then verify power has been discharged before connecting the adapter to the
network.