Configuring the PROFIBUS Master

Chapter 4

1.

From the Tools menu, choose Install new GS*-file.

A dialog box appears for you to browse for the location of the GSD file.

2.

Select the file to install, and click Open.
If the file already exists in the configuration file path, you will be prompted
to overwrite the file.

3.

You will be prompted to associate the GSD configuration file with a
bitmap image of the slave.

4.

Use the File/Open dialog box to browse for the location of the image
file(s) to use.
If you have no specific bitmap file, you may Cancel the bitmap upload
which then provides a generic slave icon to use in the Bus Configuration
window for this slave.

5.

Select the image files provided with the GSD file for the 25-COMM-P
adapter.
A screen prompt appears showing the newly added slave in the treeview.