Adapter Parameters

Appendix B provides information about the adapter parameters.

The adapter parameters are displayed in a Numbered List view order.

Device Parameters

Topic

Page

Device Parameters

77

Parameter

No.

Name and Description

Details

01

[MultiDrv Sel]
Displays the single-drive or multi-drive operating mode based
on Host parameter C169 [MultiDrv Sel] setting.

Values:

0 = Disabled
1 = Network Opt
2 = EtherNet/IP

Type:

Read Only

02

[DLs From Net Act]
Displays the number of network-to-drive Datalinks that the
drive is using based on the I/O connection opened by the
controller.

Minimum:

0

Maximum:

4

Type:

Read Only

03

[DLs To Net Act]
Displays the number of drive-to-network Datalinks that the
controller is using based on the I/O connection opened by the
controller.

Minimum:

0

Maximum:

4

Type:

Read Only

04

[Net Addr Src]
Displays the source from which the adapter’s node address is
taken. This will be either the Node Address switches (see

Setting the Endianness and Node Address Using the DIP
Switches on page 14

) or the value of Device parameter

05 [Net Addr Cfg].

Values:

0 = Switches
1 = Parameters

Type:

Read Only

05

[Net Addr Cfg]
Sets the network node address for the adapter when Device
parameter 06 [Net Addr Src] is set to 1 “Parameters”.

Default:

126

Minimum:

1

Maximum:

126

Type:

Read/Write

Reset Required:

Yes

06

[Net Addr Act]
Displays the actual network node address used by the adapter.

Minimum:

1

Maximum:

126

Type:

Read Only

07

[Net Data Format]
Displays the byte alignment for the network data as selected
with the Byte Swap switch 8 (see

Node Address Switch Settings

on page 15

).

Values:

0 = Ltl Endian
1 = Big Endian

Type:

Read Only