Tag Definitions

Table 6 - GSR DI(S) Module Input Tags

Name

Data Type

Definition

Slotx_GSR_DIS_IN01

BOOL

IN01 Status - Indicates whether input circuit 1 is On or Off.
0 = The input channel is Off.
1 = The input channel is On.

Slotx_GSR_DIS_IN02

BOOL

IN02 Status - Indicates whether input circuit 2 is On or Off.
0 = The input channel is Off.
1 = The input channel is On.

Slotx_GSR_DIS_SingleWireSafetyIn

BOOL

Single Wire Safety Input Status - Indicates whether the
Single Wire Safety input (L12) is On or Off.
0 = The Single Wire Safety input signal is Off.
1 = The Single Wire Safety input signal is On.

Slotx_GSR_DIS_ResetRequired

BOOL

Reset Required Indication - This indication turns On (1)
when all monitored input conditions are On and the safety
relay Output is Off (0).

Slotx_GSR_DIS_CrossLoopOK

BOOL

Cross Loop OK - Indicates whether the safety relay is
detecting a cross loop fault on one of the input circuits.
0 = Cross loop fault
1 = No fault

Slotx_GSR_DIS_SafetyOutput

BOOL

Safety Output Status – Indicates whether the safety
output channels are On or Off.
0 = The safety output channels are Off.
1 = The safety input channels are On.

Slotx_GSR_DIS_RecoverableFault

BOOL

Recoverable Fault Status – Toggles On (1) for one scan
when the safety relay has detected unexpected operation of
a monitored safety device. See S12 OpenWire, S22
OpenWire, S32 OpenWire, S42 OpenWire, Cross Loop Fault,
Invalid Switch Setting, and Reset Held On (

page 52

) for

details.
0 = No fault
1 = Fault

Slotx_GSR_DIS_NonRecoverableFault

BOOL

Non-Recoverable Fault Status – Toggles On (1) for one
scan when the safety relay has detected unexpected
internal operation or failed a pulse check. See
NonRecoverableFault_A and NonRecoverableFault_B (

page

52

) for details.

0 = No fault
1 = Fault

Slotx_GSR_DIS_S12

BOOL

S12 Status – Indicates whether terminal S12 of circuit IN01
is On or Off.
0 = The terminal is Off.
1 = The terminal is On.

Slotx_GSR_DIS_S22

BOOL

S22 Status – Indicates whether terminal S22 of circuit IN02
is On or Off.
0 = The terminal is Off.
1 = The terminal is On.

Slotx_GSR_DIS_S32

BOOL

S32 Status – Indicates whether terminal S32 of circuit IN02
is On or Off.
0 = The terminal is Off.
1 = The terminal is On.

Advertising