Tag Definitions

Appendix D

Slotx_GSR_GLP_NonRecoverableFault_A

SINT

Non-Recoverable Fault Processor A – Indicates a
non­recoverable fault has been recorded by Safety
Processor A. See

Table 12 on page 60

for a list of non-

recoverable fault codes.

Slotx_GSR_GLP_NonRecoverableFault_B

SINT

Non-Recoverable Fault Processor B – Indicates a
non­recoverable fault has been recorded by Safety
Processor B. See

Table 12 on page 60

for a list of non-

recoverable fault codes.

Slotx_GSR_GLP_GateOpenFault

BOOL

Gate Open Fault - Indicates the Gate inputs, S12,
S22, unexpectedly opened.
0 = No Fault
1 = Fault

Slotx_GSR_GLP_InvalidSwitchSetting

BOOL

Invalid Switch Setting Fault – The rotatory switch
configuration does not match the configuration
stored in the safety relay.

Slotx_GSR_GLP_LockRequestGateOpenFault

BOOL

Lock Request/Reset Gate Open Fault - Indicates
the gate was open during a lock or reset request.
0 = No fault
1 = Fault

Slotx_GSR_GLP_Overspeed_SL2

BOOL

Over-speed SL2 Fault - Indicates the monitored
speed exceeded the configured maximum speed limit
settings for SL2.
0 = No fault
1 = Fault

Slotx_GSR_GLP_Overspeed_SL1

BOOL

Over-speed SL1 Fault - Indicates the monitored
speed exceeded the configured maximum speed limit
settings for SL1.
0 = No fault
1 = Fault

Slotx_GSR_GLP_LockRequestHeldOn

BOOL

Lock Request Held On Fault – Indicates the lock
request signal On (1) for longer than the maximum
time of 3000 ms.
0 = No fault
1 = Fault

Slotx_GSR_GLP_UnLockRequestHeldOn

BOOL

Unlock Request Held On Fault – Indicates the
unlock request signal On (1) for longer than the
maximum time of 3000 ms.
0 = No fault
1 = Fault