Rockwell Automation 440R Guardmaster EtherNet/IP Network Interface User Manual User Manual

Page 58

Advertising
background image

58

Rockwell Automation Publication 440R-UM009B-EN-P - February 2014

Appendix D

Tag Definitions

Table 11 - GSR GLP Module Input Tags

Name

Data Type

Definition

Slotx_GSR_GLP_S12_S22_Status

BOOL

S12, S22 Status – Indicates whether two channel
input channel S12/S22 is On or Off.
0 = The two channel input is Off.
1 = The two channel input is On.

Slotx_GSR_GLP_SingleWireSafetyIn

BOOL

Single Wire Safety Input Status – Indicates
whether the Single Wire Safety input (L12) is On or
Off.
0 = The Single Wire Safety input signal is Off.
1 = The Single Wire Safety input signal is On.

Slotx_GSR_GLP_LockRequest_S44

BOOL

Lock Request S44 Indication – This indication
whether the Lock Request input (S44) is On or Off.
0 = The Lock Request input is Off.
1 = the Lock Request input is On.

Slotx_GSR_GLP_UnLockRequest_S54

BOOL

Unlock Request S54 Indication – This indication
whether the Unlock Request input (S54) is On or Off.
0 = The Unlock Request input is Off.
1 = the Unlock Request input is On.

Slotx_GSR_GLP_RecoverableFault

BOOL

Recoverable Fault Status – Toggles On (1) for one
scan when the safety relay has detected unexpected
operation of a monitored safety device. See Gate
Open Fault, Invalid Switch Setting, Lock Request Gate
Open Fault, Overspeed SL2, Overspeed SL1, Lock
Request Held On, and UnLock Request Held On (

page

59

) for details.

0 = No fault
1 = Fault

Slotx_GSR_GLP_NonRecoverableFault

BOOL

Non-Recoverable Fault Status – Toggles On (1) for
one scan when the safety relay has detected
unexpected internal operation or failed a pulse check.
See NonRecoverableFault_A and
NonRecoverableFault_B (

page 59

) for details.

0 = No fault
1 = Fault

Slotx_GSR_GLP_51

BOOL

51 Status – Indicates whether terminal 51 is On or
Off.
0 = The terminal is Off.
1 = The terminal is On.

Slotx_GSR_GLP_L61

BOOL

L61 Status – Indicates whether terminal L61 is On or
Off.
0 = The terminal is Off.
1 = The terminal is On.

Slotx_GSR_GLP_Y32

BOOL

Y32 Status – Indicates whether terminal Y32 is On or
Off.
0 = The terminal is Off.
1 = The terminal is On.

Slotx_GSR_GLP_S11

BOOL

S11 Status – Indicates whether terminal S11 is On or
Off.
0 = The terminal is Off.
1 = The terminal is On.

Slotx_GSR_GLP_S21

BOOL

S21 Status – Indicates whether terminal S21 is On or
Off.
0 = The terminal is Off.
1 = The terminal is On.

Slotx_GSR_GLP_L11

BOOL

L11 Status – Indicates whether terminal L11 is On or
Off.
0 = The terminal is Off.
1 = The terminal is On.