Rockwell Automation 1791-XXXX ANALOG BLOCK I/O User Manual

Page 46

Advertising
background image

Analog Block Applications Using

Block Transfers

Chapter 4

4-6

Description

Decimal Bit

(Octal Bit)

Word

Word 25

Bits 00Ć15 (00Ć17)

High alarm level for input channel 3. When the input value for this channel is greater than the

high value, the corresponding high alarm bit is set in the BTR.

Word 26

Bits 00Ć15 (00Ć17)

Alarm deadband for input channel 3. This field creates a hysteresis effect on the low and high

alarms. For an alarm condition to be removed, the input signal must go above the low alarm

limit or below the high alarm limit by an amount equal to the specified deadband. Alarm

deadband values must be less than or equal to one half the difference of the high and low

alarm values.

Table 4.C

Filter Time Selection

Filter Time

Bit Settings

Filter Time

Bit 03 Bit 02 Bit 01 Bit 00

Default Ć no filter

0

0

0

0

Do not use.

0

0

0

1

200ms

0

0

1

0

300ms

0

0

1

1

400ms

0

1

0

0

500ms

0

1

0

1

600ms

0

1

1

0

700ms

0

1

1

1

800ms

1

0

0

0

900ms

1

0

0

1

1000ms

1

0

1

0

1100ms

1

0

1

1

1200ms

1

1

0

0

1300ms

1

1

0

1

1400ms

1

1

1

0

1500ms

1

1

1

1

Advertising