Dynamic ip address assignment by port – Rockwell Automation 1783-EMS08T Stratix 6000 Ethernet Managed Switch User Manual User Manual

Page 31

Advertising
background image

Rockwell Automation Publication 1783-UM001D-EN-P - January 2013

31

Network Services Setup

Chapter 2

4. Type your subnet and gateway addresses for the network.
5. Type the primary and secondary DNS server addresses.
6. Type the domain name, if applicable.
7. Use DHCP Pool From and DHCP Pool To to assign a range of addresses.

The switch assigns an address within the specified range.

8. Enable Dynamic BOOTP to answer BOOTP requests.
9. Type the number of days to specify the default lease time for DHCP

requests.

The default value is 7 days.

10. Click Apply Changes and cycle power for the changes to take effect.

Dynamic IP Address Assignment by Port

The 1783-EMS switch has the ability to assign IP addresses based on the port
where the device is connected. When used properly, this feature provides for easy
replacement of Ethernet equipment on the factory floor.

Use these steps to set up dynamic IP address assignment by port.

1. Establish a connection with the 1783-EMS switch.
2. Click Network Services Setup and DHCP Configuration.
3. From the DHCP Server pull-down menu, choose On - Assigned by Port.

By default, this setting is off.

IMPORTANT

If multiple devices are connected to a port with an uplink to another switch,
the IP address is sent to the first device to request it from the port. If a field is
set to an address of 0.0.0.0, a DHCP request on the port is ignored.

Most applications with programmable controllers do not require changes to
the DNS, domain name, and lease time fields. If these functions do not apply to
your network, leave these fields at their default value.

Advertising