Table 7 - Configuration Options for Ports 1…8

Configuration Option

Description

Transmit & Receive

Controls port communication.
Values:
Both (default)
Tx
Rx
None

Negotiation

Indicates whether the port configuration settings are autonegotiated. Select
None to manually configure the port.
Values:
None
Auto (default)

Rate

Autonegotiates 10 or 100 mbit/s depending on the connected device. The
speed must be manually selected if the negotiation parameter is None.
Values:
10
100

Duplex Mode

Autonegotiates half-duplex or full-duplex mode based on the connected
device. The duplex mode must be manually selected if the negotiation
parameter is changed to None.
Values:
Half—The switch can either send or receive data, but cannot do both

simultaneously.

Full—The switch can simultaneously send and receive data.

Flow Control

Prevents buffers from over filling.
Values:
OFF
ON (default)

TIP

Ports set for autonegotiation default to half-duplex mode if the connected
devices are not configured to autonegotiate.

Turning off autonegotiation disables the auto-MDIX feature. In this case,
crossover cables may be needed to establish communication to the connected
device.