Table 6

lists Receive (Rx) counters.

Table 6 - Rx Counters

Counter

Description

Rx Octets

Total good octets received on selected port.

Rx Undersize Pkts

Good packets that are under 64 octets long.

Rx Pause Pkts

Pause packets received by this port.

Pkts64 Octets

Data packets = 512 bits.

Pkts65to127 Octets

Data packets = 520…1016 bits.

Pkts128to255 Octet

Data packets = 1024…2040 bits.

Pkts256to511 Octet

Data packets = 2048…4088 bits.

Pkts512to1023 Octet

Data packets = 4096…8184 bits.

Pkts1024to1522 Octet

Data packets = 8192…12,176 bits.

RxOversize Pkts

Packets over 12,176 bits or 1523…1536 octets.

RxJabbers Pkts

Packets longer than 1522 octets and have an error, usually
caused by a faulty device.

RxAlignment Errors

Packets between 64 and 1522 octets and have an error.

RxFCS Errors

Packets received (between 645 and 1522 octets) with FCS
(frame check sequence) not matching.

RXGoodPkts

Octets received with no errors.

RXDrop Pkts

Packets dropped due to lack of resources, such as
bandwidth or input buffer.

RxUnicast Pkts

Unicast packet received (only one receiving host).

RxMulticast Pkts

Multicast packets received (many receiving hosts).

RxBroadcast Pkts

Received by all hosts on the network.

RxSAChanges

Number of times the Source address of a good packet has
changed value.
A count greater than 1 indicates a repeater based
network.

RxFragments

Packets received less than 64 octets.

RxExcessSizeDisc

Packets received greater than 1536 octets and discarded
due to excessive length.

RxSymbolError

Invalid data symbol detected.