Diagnostics

Chapter 3

Counters are displayed in hex where an octet equals 8 bits.

Table 5

lists Transmit

(Tx) counters.

Table 5 - Tx Counters

Counter

Description

Tx Octet Count

Total of transmitted good octets from the selected port.

Tx Drop Pkts Count

Packet is not acknowledged by the receiving host.

Tx BroadcastPkts Count

Number of good packets sent with destination of
everyone. Receivers are unspecified.

Tx MulticastPkts Count

Packets sent to members of multicast group. One terminal
to many hosts.

Tx UnicastPkts Count

In contrast with multicast, consists of one terminal
transmitting to one host.

Tx Collisions Count

Two terminals transmit packets at the same time causing
them to collide. Collision Count should be very low.
Collisions could indicate a faulty device on the network.

Tx SingleCollision Count

Packet collides with one other terminal’s transmitted
packet.

Tx MultipleCollision Count

Packet collides with more than one terminal’s transmitted
packets.

Tx DeferredTransmit Count

Number of packets delayed because the network is busy.
The higher the number, the less deterministic your
network.

Tx LateCollision Count

Collision is detected later than the 512 bits into the packet
transmission.

Tx ExcessiveCollision Count

Network device is not acting in compliance with a flow
control request.

Tx PausePkts Count

Pause frames sent by this port.

Advertising