Preface
APS Quick Start for New Users
3–6
The display shown below appears.
Bul. 1761
MicroLogix 1000
1747-L511
5/01 CPU - 1K USER MEMORY
1747-L514
5/01 CPU - 4K USER MEMORY
1747-L524
5/02 CPU - 4K USER MEMORY
1747-L532
5/03 CPU -12K USER MEMORY
1747-L541
5/04 CPU -12K USER MEMORY
F8
SAVE &
EXIT
NAME:
F2 Processor: Bul. 1761 MicroLogix 1000
F5
CONFIGR
I/O
Press a Function key or Enter File Name
CREATE PROCESSOR FILE
PROCESSOR
ESC exits/Alt-U aborts changes
INPUTS
OUTPUTS
F2
SELECT
PROC
F6
ADJUST
FILTERS
2.
Enter the name
GETSTART
.
The prompt line asks you to enter a file name. Type
GETSTART
, then press
[ENTER]
. GETSTART appears in the Create Processor File window.
3.
Enter the appropriate processor catalog number.
The Create Processor File window lists the default processor, Bul. 1761. Our
controller uses the 1747-L524 processor. Cursor down to highlight it. (If you
are using a different processor, use the cursor keys to locate the appropriate
processor in the upper option window.) Press
CONFIG
OFFLINE
CONFIG
SELECT
PROC
F2
.
4.
If you have selected a fixed controller and are not using an expansion chassis,
the controller configuration is complete at this point. Press
CONFIG
OFFLINE
CONFIG
SAVE &
EXIT
F8
and go to