Creating a Processor File
3–9
For our controller, the completed option window appears as follows:
RACK 1
=
1746-A4 4-SLOT Backplane
RACK 2
=
NOT INSTALLED
RACK 3
=
NOT INSTALLED
SLOT
CATALOG #
CARD DESCRIPTION
*0
1747-L524
5/02 CPU - 4K USER MEMORY
*1
1746-IA4
4-Input 100/120 VAC
*2
1746-IA8
8-Input 100/120 VAC
*3
1746-OA8
8-Output(TRIAC) 100/240 VAC
4
5
6
7
8
Press a function key
I/O CONFIGURATION FOR:GETSTART
F6
F7
F4
F5
DELETE
SLOT
UNDEL
SLOT
MODIFY
RACKS
MODIFY
SLOT
F8
EXIT
ESC exits
F1
F2
READ
CONFIG
ONLINE
CONFIG
F9
SPIO
CONFIG
7.
Create the archive file GETSTART.
Press
CONFIG
OFFLINE
CONFIG
EXIT
F8
, then
CONFIG
OFFLINE
CONFIG
SAVE &
EXIT
F8
. Archive file GETSTART is created on your
computer hard disk and placed in the Offline Processor File window.
8.
Press
CONFIG
OFFLINE
CONFIG
SAVE
F9
TO FILE
to save GETSTART as the new default file.