background image

Preface

APS Quick Start for New Users

4–4

After you have done a), b), or c), the following display appears:

Press a Function Key or Enter File Name

REM PROG

L524

PROC Addr 1

\IPDS\ARCH\SLC500

F1

BEGIN

RESTORE

Name

Size

Date

GETSTART

8586

01-03-92

F7

DEFINE

DIR

2.

Select and accept file GETSTART.

The cursor is located in the right-hand window, which lists all of the processor
files saved on disk. Move the cursor to the file GETSTART if it is not already

there. Press

CONFIG

OFFLINE

CONFIG

BEGIN

RESTORE

F1

. If the processor is in the program mode, the file is

restored (downloaded). If the processor is in the run mode, you are asked

“Change Processor Mode to Program?”. Press

CONFIG

OFFLINE

CONFIG

YES

F8

. File GETSTART is

restored (downloaded).