Preface

APS Quick Start for New Users

A–8

6.

Accept the rung.

Press

[ESC]

, then

CONFIG

OFFLINE

CONFIG

ACCEPT

RUNG

F10

.

7.

Enter a third rung and an XIC instruction.

Press

CONFIG

OFFLINE

CONFIG

INSERT

INSTR

F4

, then

CONFIG

OFFLINE

CONFIG

BIT

F1

, then

CONFIG

OFFLINE

CONFIG

XIC

-] [-

F1

. Type the address

T4:0/DN

, then press

[ENTER]

. “DN” represents the timer done bit.

8.

Enter an OTE instruction.

Press

CONFIG

OFFLINE

CONFIG

BIT

F1

, then

CONFIG

OFFLINE

CONFIG

OTE

-( )-

F3

. Type the address

O:3/4

, then press

[ENTER]

.

9.

Accept the rung.

Press

[ESC]

, then

CONFIG

OFFLINE

CONFIG

ACCEPT

RUNG

F10

, then

[ESC]

.

10. Exit the edit mode.

Press

[ESC]

.