Preface
APS Quick Start for New Users
3–12
Your completed ladder program and rung comment should look like this:
( )
Press a function key
(file 2, rung 0)
offline no forces File GETSTART
F2
CONFIG
DISPLAY
F9
FORCE
END
F10
EDIT
F3
EXIT
F6
F7
SEARCH
GENERAL
UTILITY
F5
DOCUMNT
O:3
0
] [
I:1
0
Input pushbutton turns on output pilot light
F8
DATA
MONITOR
Save the Processor File
Complete the following steps to save the processor file to disk:
1.
Return to the Program Directory.
Press
CONFIG
OFFLINE
CONFIG
EXIT
F3
.
2.
Save the file to disk.
Press
CONFIG
OFFLINE
CONFIG
SAVE
F2
. Accept the default Save options by pressing
CONFIG
OFFLINE
CONFIG
YES
F8
.
3.
Return to the APS menu.
Press
CONFIG
OFFLINE
CONFIG
RETURN
TO MENU
F3
.