Rockwell Automation 57C650 AutoMax Programming Executive Version 3.8 User Manual

Page 103

Advertising
background image

6Ć5

Configuring Racks

M/N 57C429 RĆNet Network Interface Module

If you are adding an RĆNet Interface module, you must

enter the node number as a hexadecimal value. (The

same hexadecimal number must be physically set on the

faceplate on the actual module.)
M/N 57C424 MaxPak III Serial Interface Module

If you are adding a MaxPak III Serial Interface Module, you

must enter the drop number. (The same drop number

must be physically set on the faceplate on the actual

module.)
B/M 57552 Universal Drive Controller Module

The Universal Drive Controller (UDC) module (B/M 57552

and B/M 57652) is used to provide drive control in

Distributed Power Systems (DPS). Up to 10 UDC modules

can be added to an AutoMax rack. UDC modules can be

mixed with other Reliance drive control modules in the

same rack. A UDC module can be added to any slot in the

rack except slot 0 and those slots already designated as

logical slots for an Ethernet module or a Common Memory

module. When you add a UDC module to the rack, you

must also select the type of drive you want to connect to

ports A and B on the module. See the Configuration and

Programming instruction manual for your specific drive

and regulator type for instructions on how to configure the

UDC module and its associated drive components. You

can begin entering drive parameters by selecting the

Configure Parameters command. See section 6.4 for more

information. Note that you will only be able to add

B/M 57652 to the rack beginning with V3.5 of the

Executive software. B/M 57652 can be used in the rack

configuration regardless of whether you have B/M 57552

or B/M 57652 in the rack itself.

Step 4.

Select one of the following: Add Next if you want to add

this module and then add another module in the next

available slot; Skip Slot if you want to add this module and

then leave the next slot empty; OK to add the module and

return to the Rack Configurator window; Cancel to return

to the Rack Configurator window without adding a

module.

Figure 6.3 Ć Adding a Module, Part 2