LĆ3

AutoMax Bill of Material Generator

Drive for temporary files: If different than the default, enter the drive used

for temporary workspace.

Step 5. After entering the last field, press TAB or ENTER to begin generating the

bill of material file. When the file is complete, the Resource Group of the

Program Manager will be displayed.
The bill of material file is contained in the system directory

(<d>:\<library>\<system>) and is named <system>.BM.

Step 6. To print the bill of material for a system, access the Main Group and

select the File Manager.

Step 7. Access the system directory that contains the desired <system>.BM

file.

Step 8. Choose <system>.BM from the list of files, then select Print from the

File menu.

Step 9. When the billĆofĆmaterial file has finished printing, use the Control menu

to close the File Manager. Then minimize the Program Manager to return

to your application.

Note:

The library directory contains the source file (GENBM.PRG) for the

AutoMax Bill of Material Generator. This file is intended to be a readĆonly

file. You can access it by using your text editor.