Rockwell Automation 57C650 AutoMax Programming Executive Version 3.8 User Manual

Page 126

Advertising
background image

7Ć14

AutoMax Programming Executive Version 3.x

D Analog Rail

Local: N/A

Remote: mmdpr

Example: if you designate PB as the character string, a digital input

module in slot 12, register 5, bit 2 would be named PB12502@.
Follow the instructions below to automatically name an I/O point:

Note that the Auto Name option will write over any text in the selected

register/bit location.
Step 1.

Select the I/O points for which you want names assigned.

Step 2.

Select Auto Name from the Variables menu. The

Autoname dialog box will be displayed.

Step 3.

Enter a variable prefix of 1 to 4 characters (letters and

underscore only). The Executive software will assign

names and descriptions for the I/O points as described

above. The Description will be the same as the functional

name displayed for each I/O point.

7.7.6

Substituting Variable Names

Variable names within a view can be changed by substituting

characters within their names. For example, if you enter *A00 as the

search string and *B99 as the replace string, variable name PBA00

would be changed to PBB99. Follow the instructions below to

substitute variable names. See figure 7.3 for the screen display.

Figure 7.3 Ć Substitute Variable Names

Step 1.

Select the variable names you want to change (unless you

want all matches found; see step 5).

Step 2.

Select Substitute from the Variables menu. The Substitute

Selected Variables dialog box will be displayed.

Step 3.

Enter the Search String and Replace String.