5Ć26

AutoMax Programming Executive Version 3.x

is a floppy drive; otherwise, AutoMax assumes a hard

drive.
Library Ć Enter the library directory to copy the rack(s) from

or to.
Format Floppies Ć Select if you want to format destination

diskettes.
High Capacity Ć Select if you want to format and/or write to

high density diskettes. The appropriate diskette capacity

will be displayed.
Rack(s) Ć The Executive software will list the rack(s)

selected when the Transfer command was called. If you

are transferring out of the current library, make certain that

this field lists all of the racks you want to transfer. If you are

transferring racks in, enter the rack names separated by

commas or spaces.

Step 4.

Select which of the following groups of files you want to

transfer with each rack:
Object files Ć application task object files, parameter object

files, and rack configuration object file(s).
CrossĆreference files
Transfer tokens

Step 5.

Select Help for information relevant to the Transfer

procedure, Cancel to return to the System Configurator

without transferring a rack, or OK to begin the rack

transfer.

Figure 5.13 Ć Transfer Rack