3-4

GV3000/SE Drive Version 6 Regulator Board Installation Instructions

Step 4.2. Drives with option boards only: Remove the Regulator board ribbon

connector from the option board. The connector is held in place by retaining
clips. Spread these clips to release the connector.

Step 4.3. Remove the old Regulator board from the keypad bracket. The board is

fastened with two metal screws with lock washers and two plastic rivets.

To remove a plastic rivet, pull the post from the rivet body. Remove the body
of the rivet. Use a small pair of wire cutters or a similar tool to pry these
pieces loose. Do not cut the rivets.

Step 4.4. Slide the old Regulator board out of the keypad bracket.

Step 4.5. Note the settings of jumpers J4 and J17 on the old Regulator board. These

jumpers are located above the center of the terminal strip as shown in
figure 3.3.

Step 5.

Install the New Regulator Board in the Keypad Bracket

Refer to figure 3.4 for component locations.

Step 5.1. Remove the new Regulator board from its anti-static wrapper. Make sure

the jumper settings on the new board match those on the old board.

Step 5.2. Slide the new Regulator board into the keypad bracket. Position the board

so that seven-segment displays appear in the display window in the
keypad.

Step 5.3. Connect the green-striped keypad ribbon cable to the new Regulator board.

Align the ribbon cable connector with the Regulator board connector and
carefully push the keyboard cable in until it snaps into place. Verify that it is
locked into position by gently tugging on the cable.

Figure 3.3 – Location of Jumpers J4 and J17 on the Regulator Board

34

-Pi

n R

ibb

on

C

a

ble

J8

J4

J17

USER I/O TERMINAL STRIP

26
-Pin

R
ibb

on C

a

ble

J5

J9

USER DISPLAY

J3

J7

Advertising