Rockwell Automation GV3000/SE V.6 Regulator Board 0-56921-6xx, 413338-6BU, 0-56940-6xx, 814.61.00 User Manual
Page 55
Advertising
![background image](/manuals/580986/55/background.png)
8-2
GV3000/SE Drive Version 6 Regulator Board Installation Instructions
Important: Read and understand the warning labels on the outside of the drive
before proceeding.
Step 1.
Shut Down the Drive
Step 1.1. Disconnect, lock out, and tag all incoming power to the drive.
Step 1.2. Wait five minutes for the DC bus capacitors to discharge.
Step 1.3. Remove the cover by removing the six cover screws.
Important: Read and understand the warning labels on the inside of the drive before
proceeding.
Figure 8.1 – Regulator Board Location in 60 to 100 HP @ 460 VAC Drives
Keypad
Regulator
Board
Power Module
Interface
Board
47
45
Advertising