6-2

GV3000/SE Drive Version 6 Regulator Board Installation Instructions

If the drive is panel-mounted, this procedure will be easier to perform if the drive is
removed from the panel.

Some steps are only required if an option board, such as the AutoMax Network option
board, is installed. These steps are preceded by the text “Option board only.”

Unless otherwise indicated, keep all hardware that is removed. You will need it for
reassembly. This includes option boards, screws, lock washers, and rivets.

Important: Read and understand the warning labels on the outside of the drive

before proceeding.

Step 1.

Shut Down the Drive

Step 1.1. Disconnect, lock out, and tag all incoming power to the drive.

Step 1.2. Wait five minutes for the DC bus capacitors to discharge.

Step 1.3. Remove the cover by loosening the four cover screws.

Important: Read and understand the warning labels on the inside of the drive before

proceeding.

Figure 6.1 – Regulator Board Location in 15 to 25 HP @ 460 VAC Drives

Front View

SPEED

Option Board

Regulator Board

Top View