5-4

GV3000/SE Drive Version 6 Regulator Board Installation Instructions

Step 3.9. Turn the Regulator board assembly over and remove the insulator from the

keypad bracket by removing a fixing screw (with lock washer) and a rivet

from the keypad bracket.

Step 4.

Remove the Regulator Board from the Keypad Bracket

Step 4.1. Drives with option boards only: Remove the option board from the keypad

bracket. The option board is held in place by four fasteners.

The option board fasteners might include plastic rivets. To remove a plastic
rivet, pull the post from the rivet body. Remove the body of the rivet. Use a

small pair of wire cutters or a similar tool to pry these pieces loose. Do not
cut the rivets.

Step 4.2. Remove the old Regulator board from the keypad bracket. The board is

fastened with two metal screws with lock washers and two plastic rivets.

Figure 5.3 – Regulator Board’s Connection to Option Board, Keypad, and Base Board

Regulator Board

Top View

Ribbon Cable
Connecting
Regulator Board and
Base Board

Option Board

To Base Board

Front

Ribbon Cable
Connecting
Regulator Board and
Option Board

Metal Screw

Ribbon Cable
Connector to
Connect Base
Board

Ribbon Cable
Connector to
Connect Keypad

Plastic Rivet

Terminal Strip

Ribbon Cable
Connector to
Connect Option
Board

Back Side of

Insulator

Rear View of Regulator Board

Regulator Board