PMI Regulator Operating Modes
3-1
C
HAPTER
3
PMI Regulator Operating Modes
The PMI Regulator’s default operating mode is idle. All other operating modes are
selected by the programmer in the Drive Control register (100/1100). Table 3.1 shows
the available operating modes. Note that the operating modes are mutually exclusive,
i.e., only one mode may be enabled at a time (this is checked by the interlock tests).
The PMI Regulator’s operating modes are shown in figure 3.1 and are described in the
following sections.
Table 3.1 – PMI Regulator Operating Modes
Operating
Mode
Drive Control
Register Bit
Mode Description
Idle
N/A
The PMI Regulator’s default operating mode during which no
algorithms are running.
Enable PMI Run
0
Executes the control algorithms.
Enable Tuning
1
Calculates gain values for the control algorithm.
Bridge Test
Enable
2
Performs a test to verify gate cable connections and power
devices.