Rim installation instructions (continued), Passport 1000 pg exit device, 3 - chassis cover instructions – SARGENT Passport 1000 PG Exit Devices User Manual

Page 10: 4 - wire cover instructions (wood doors only)

Advertising
background image

4. Secure wire cover plate to door directly above chassis cover (note orientation) using two

(2) #6 x 1/2” flat head security torx wood screws (Fig. 4A1 and 4A2).

NOTE: Position lower edge of cover
plate against the chassis cover
to ensure no wires are visible.

(2) dia. 3/32” by

1/2” deep holes

Fig. 4A1

Inside of door

Wire

cover

(2) #6 x 1/2”

flat head security

torx wood

screws

This side down

Fig. 4A2

(4) #8-32 x 5/8” oval

head machine

screws

Passport

gasket

Outside

Passport

trim

Outside of door

Fig. 5A

Rim Installation Instructions (Continued)

Fig. 3A

Inside of door

1. Align wire cover plate with chassis side against exit chassis cover and mark hole positions.
2. Drill (2) 3/32” diameter by 1/2” deep holes as shown (Fig. 4A1).
3. Ensure stamped side of plate goes against door.

5A - Installation of Outside Escutcheon with

Weatherseal Gasket (Optional)

Back side of

wire cover plate

Chassis Cover

NOTE: For non-fire rated door applications, an optional gasket
may be used as a weatherseal between the escutcheon
and the outside door surface. Peel off adhesive backing
and attach to (outside) escutcheon (Fig. 5A).

3 - Chassis Cover Instructions

Secure chassis cover to chassis using
(4) #8-32 x 5/16” oval head machine screws.

4 - Wire Cover Instructions

(Wood doors only)

10/31/12

A7809B 10

Copyright © 2012, Sargent Manufacturing Company

, an ASSA ABLOY Group company

. All rights reser

ved.

Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.

Passport 1000 PG Exit Device