Mortise installation instructions (continued), Passport 1000 pg exit device – SARGENT Passport 1000 PG Exit Devices User Manual

Page 15

Advertising
background image

Fig. 2B2

Inside of door

Exit chassis

Grounding harness

(wood doors only)

(2) 1/4” x 2-3/8”

flat head machine

screws (secures ET)

ET control

Fig. 2A

Wire harness

(from motor)

Mortise

lock body

1. Route “ET” harness along track cutout for wood doors and access hole for metal doors.
2. Mount exit chassis carefully.

Do not pinch harness wires.

3. Position exit chassis on door with lever arm under rear section of mortise lock.
4. Using (2) 1/4-20 x 2-3/8” flat head screws, attach chassis to “ET” control.

(2) #12 x 1”

wood screws

or

(2) #12-24 x

1/2” machine

screws

Latchbolt

Lever arm

Lever

Chassis

Mortise Installation Instructions (Continued)

A. Outside Trim

1. Slide mortise lock into door

and securely fasten with (2)
flat head screws.

2. For exterior applications, gasket

(52-0263) should be used to
seal between “ET” escutcheon
and outside door surface.

3. Route “ET” harness through

wire cutout and out other
side of door.

4. Place “ET” control on door

with spindle inserted through
mortise lock.

B. Exit Chassis:

Fig. 2B1

Detail

Outside of

door

ET wire harness

(from motor)

ET Gasket

2 – Installation of Outside Exit Trim (ET),

Exit Chassis and Cylinder

15

A7809B

Copyright © 2012, Sargent Manufacturing Company

, an ASSA ABLOY Group company

. All rights reser

ved.

Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.