Mortise installation instructions (continued), Passport 1000 pg exit device, 3 – chassis cover instructions – SARGENT Passport 1000 PG Exit Devices User Manual

Page 17: 4 - wire cover instructions (wood door only)

Advertising
background image

Fig. 4A

Wire

cover

(2) #6 x ½” flat head security

Torx wood screws

This side down

Inside of door

Chassis

cover

(4) #8 - 32 x 5/16”

Oval head machine

screws

Mortise Installation Instructions (Continued)

3 – Chassis Cover Instructions

Secure chassis cover to chassis using
(4) #8 - 32 x 5/16” oval head machine screws.

Note: Required for 12- Fire Rated doors only.
1. Align wire cover plate with chassis side against exit chassis

cover and mark hole positions.

2. Drill (2) 3/32” dia. by 1/2” deep holes as shown.
3. Stamped side of plate goes against door.
4. Secure wire cover plate to door directly above chassis cover

(note orientation) using two (2) #6 x 1/2” flat head security
torx wood screws.

Note: Position lower edge of cover plate against the chassis
cover to ensure no wires are visible.

(2) 3/32” dia.

by 1/2” deep

holes

Inside of door

Back side of

wire cover plate

4 - Wire Cover Instructions (Wood Door Only)

10/31/12

A7809B 17

Copyright © 2012, Sargent Manufacturing Company

, an ASSA ABLOY Group company

. All rights reser

ved.

Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.