4-23

2. Verify that the wire ends have been stripped correctly with only

6 millimeters (¼ in) exposed. If they have not been stripped or
have been stripped incorrectly, prepare the wires in the
following way:

Wire ends stripped 6 mm

 Cut off the old stripped ends (when applicable) back to the

jacket.

 Use the small side cutters to carefully remove 102

millimeters (4 in) of the jacket, and cut away the tension
strands and any other unnecessary jacket materials.

 Using the wire strippers, select the appropriate gauge and

strip 6 millimeters (¼ in) from the end of all conductors.
Twist each wire end to prevent fraying.

3. Carefully tape together the loose bundle of wires using the

vinyl electrical tape. Form a taper covering all of the wires,
keeping it as thin as possible so that it will be able to pass
through the communication cable entry fitting on top of the
EMU.