6-42 IETG FlowHawk Manual

Ping Amplitude Choose the method for managing the

amplification of the analog signal that is sent out, or
transmitted from, the sensor. Smaller pipes typically
require weaker (quieter) amplification; larger pipes
typically require stronger (louder) amplification.

Auto Select this option to allow the monitor to

automatically optimize the amplification of the signal.

Manual Select this option to enter the percentage of

full amplification at which to transmit the signal.
Enter a percentage between 10 and 100 percent, where
100 percent represents maximum amplification.