ADS Environmental Services IETG FlowHawk QR 775012 A4 User Manual

Page 354

Advertising
background image

Specifications

A-9

Downward Ultrasonic Depth

Accuracy

3.2 millimeters (0.125 in)

Deadband

12.7 millimeters (0.5 in) or 5% of maximum range,
whichever is greater

Frequency

40 kHz

Range

12.7 millimeters (0.5 in), or 5% of maximum range
(whichever is greater) to 3.05 meters (10.0 ft)

Resolution

0.25 millimeters (0.01 in)

Drift

0.0 millimeters (0 in)

Pressure Depth (optional)

Pressure Range

0.0 – 0.34 Bar (0.0 to 5.0 PSI): up to 3.5 meters
(11.5 ft)

0.0 – 1.03 Bar (0.0 to 15.0 PSI): up to 10.5 meters
(34.5 ft)

Pressure

Accuracy

0 – 0.34 Bar (0.1 – 5.0 PSI): +/- 36 mm (1.4 in)

0 – 1.03 Bar (0.1 – 15.0 PSI): +/- 104 mm (4.1 in)

Pressure

Resolution

0.25 millimeters (0.01 in)