3-22 IETG FlowHawk Manual

either side of the pipe (between the 5:30 and 6:30 positions).
A physical offset measurement must be taken if this technique
is used. Refer to Installing the Ring in the Pipe on page 3-25.

ULTRASONIC DEPTH SENSOR

OR

SURFACE COMBO SENSOR

PEAK COMBO SENSOR

OR

SLIMLINE PEAK COMBO SENSOR

Proper positioning of sensors on the ring (showing the Surface Combo

Sensor at top and Peak Combo Sensor at bottom)

Surface Combo Sensor or Ultrasonic Depth Sensor
Mount the sensor at the twelve o'clock position (top of the
pipe) when the spreader mechanism is in the one o'clock
position

Caution: Handle all sensors and cables with extreme
care. The sensors and cables contain delicate mechanisms
and electronics. Keep sharp objects away from sensor
cables, and avoid stepping or placing heavy objects on the
cable during installation.