Dell PowerVault DR6000 User Manual

Page 103

Advertising
background image

Expanded Operating Temperature

NOTE: When operating in the expanded temperature range, ambient temperature warnings may be
reported on the LCD and in the System Event Log.

< 10% of annual operating hours

5 °C to 40 °C at 5% to 85% RH with 26 °C dew
point.

NOTE: Outside the standard operating
temperature (10 °C to 35 °C), the system can
operate down to 5 °C or up to 40 °C for a
maximum of 10% of its annual operating
hours.

For temperatures between 35 °C and 40 °C, de-

rate maximum allowable dry bulb temperature by

1 °C per 175 m above 950 m (1 °F per 319 ft).

< 1% of annual operating hours

–5 °C to 45 °C at 5% to 90% RH with 26 °C dew
point.

NOTE: Outside the standard operating
temperature (10 °C to 35 °C), the system can
operate down to –5 °C or up to 45 °C for a
maximum of 1% of its annual operating hours.

For temperatures between 40 °C and 45 °C, de-

rate maximum allowable dry bulb temperature by

1 °C per 125 m above 950 m (1 °F per 228 ft).

Expanded Operating Temperature Restrictions

• Do not perform a cold startup below 5 °C.
• The operating temperature specified is for a

maximum altitude of 3048 m (10,000 ft).

• 130 W (4 core) processor is not supported.
• Redundant power supplies are required.
• Non-Dell qualified peripheral cards and/or

peripheral cards greater than 25 W are not

supported.

• Maximum 95 W processor is supported on 3.5

inch hard drive chassis.

• Maximum 115 W processor is supported on 2.5

inch hard drive chassis.

Environmental

NOTE: For additional information about environmental measurements for specific system
configurations, see dell.com/environmental_datasheets.

Temperature

Maximum Temperature Gradient (Operating and
Storage)

20 °C/h (36 °F/h)

Storage Temperature Limits

–40 °C to 65 °C (–40 °F to 149 °F)

Temperature (Continuous Operation)

103

Advertising