Error Code

Message Information

5.

If the issue persists, see

Getting Help

.

CPU0704

Message

CPU <number> machine check error detected.

Details

System event log and operating system logs may indicate
that the exception is external to the processor.

Action

1.

Check system and operating system logs for exceptions.

If no exceptions are found, continue.

2.

Turn off the system and remove input power for one

minute.

3.

Ensure the processor is seated correctly.

4.

Reapply input power and turn on the system.

5.

If the issue persists, see

Getting Help

.

FAN0000

Message

Fan <number> RPM is less than the lower warning threshold.

Details

Fan operating speed is out of range.

Action

Remove and reinstall the fan. If the issue persists, see

Getting

Help

.

FAN0001

Message

Fan <number> RPM is less than the lower critical threshold.

Details

Fan operating speed is out of range.

Action

Remove and reinstall the fan. If the issue persists, see

Getting

Help

.

FAN1201

Message

Fan redundancy is lost.

Details

Fan has failed.

Action

Remove and reinstall failed fans or install additional fans.

HWC1001

Message

The <name> is absent.

Details

The absent device may be necessary for proper operation.
System functionality may be degraded.

Action

Reinstall or reconnect the hardware.

HWC2003

Message

The storage <name> cable is not connected, or is improperly
connected.

Details

The cable may be necessary for proper operation. System
functionality may be degraded.