Error Code

Message Information

Details

System Event Log and Operating System Logs may indicate
that the exception is external to the processor.

Action

Review System Event Log and Operating System Logs. If the
issue persists, see

Getting Help

.

CPU0001

Message

CPU <number> has a thermal trip (over-temperature) event.

Details

The processor temperature increased beyond the
operational range.

Action

Review the logs for fan failures. If no fan failures are
detected, check inlet temperature (if available) and reinstall
processor heat sink. If the problem persists, see

Getting Help

.

CPU0005

Message

CPU <number> configuration is unsupported.

Details

System is unable to boot or may run in a degraded state.

Action

Review the technical specifications for supported processor
types.

CPU0010

Message

CPU <number> is throttled.

Details

The CPU is throttled due to thermal or power conditions.

Action

Review system logs for power or thermal exceptions.

CPU0023

Message

CPU <number> is absent.

Action

Verify processor installation. If present, re-seat the
processor.

CPU0204

Message

CPU <number> <name> voltage is outside of range.

Details

Voltages outside the allowable range may damage electrical
components or may cause the system to shutdown.

Action

1.

Turn off the system and remove input power for one

minute.

2.

Ensure the processor is seated correctly.

3.

Reapply input power and turn on the system.

4.

If the issue persists, see

Getting Help

.

CPU0700

Message

CPU <number> initialization error detected.

Details

System BIOS was unable to initialize the processor.

109