Dell PowerVault DR6000 User Manual

Page 114

Advertising
background image

Error Code

Message Information

Details

System performance may be degraded, PCI device may fail
to operate, or system may fail to operate.

Action

Cycle input power, update component drivers, if device is
removable, reinstall the device.

PCI1320

Message

A bus fatal error was detected on a component at bus
<bus>device<device>function <func>.

Details

System performance may be degraded, or system may fail to
operate.

Action

Cycle input power, update component drivers, if device is
removable, reinstall the device.

PCI1342

Message

A bus time-out was detected on a component at slot
<number>.

Details

System performance may be degraded, or system may fail to
operate.

Action

Cycle input power, update component drivers, if device is
removable, reinstall the device.

PCI1348

Message

A PCI parity error was detected on a component at slot
<number>.

Details

System performance may be degraded, or system may fail to
operate.

Action

Cycle input power, update component drivers, if device is
removable, reinstall the device.

PCI1360

Message

A bus fatal error was detected on a component at slot
<number>.

Details

System performance may be degraded, or system may fail to
operate.

Action

Cycle input power, update component drivers, if device is
removable, reinstall the device.

PDR0001

Message

Fault detected on drive <number>.

Details

The controller detected a failure on the disk and has taken
the disk offline.

Action

Remove and re-seat the failed disk. If the issue persists, see

Getting Help

.

114

Advertising