Error Code

Message Information

Action

Check if the cable is present, then reinstall or reconnect.

HWC2005

Message

The system board <name> cable is not connected, or is
improperly connected.

Details

The cable may be necessary for proper operation. System
functionality may be degraded.

Action

Check if the cable is present, then reinstall or reconnect.

MEM0000

Message

Persistent correctable memory errors detected on a memory
device at location(s) <location>.

Details

This is an early indicator of a possible future uncorrectable
error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM0001

Message

Multi-bit memory errors detected on a memory device at
location(s) <location>.

Details

The memory module has encountered an uncorrectable
error. System performance may be degraded. The operating
system and/or applications may fail as a result.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM0007

Message

Unsupported memory configuration; check memory device
at location <location>.

Details

The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.

Action

Check the memory configuration. Re-seat the memory
modules. If the issue persists, see

Getting Help

.

MEM0701

Message

Correctable memory error rate exceeded for <location>.

Details

The memory may not be operational. This an early indicator
of a possible future uncorrectable error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM0702

Message

Correctable memory error rate exceeded for <location>.

112

Advertising