Dell PowerVault DR6000 User Manual

Page 116

Advertising
background image

Error Code

Message Information

Action

Install matched power supplies and review proper
configuration in this manual.

PSU0016

Message

Power supply <number> is absent.

Details

The power supply has been removed or has failed.

Action

1.

Remove and reinstall the power supply.

2.

Check cables and subsystem components in the system

for damage.

3.

If the issue persists, see

Getting Help

.

PSU0031

Message

Cannot communicate with power supply <number>.

Details

The power supply may operate, however power supply
monitoring is degraded. System performance may be
degraded.

Action

Remove and reinstall the power supply. If the issue persists,
see

Getting Help

.

PSU0032

Message

The temperature for power supply <number> is in a warning
range.

Details

System performance may be degraded.

Action

Check the system operating environment, including airflow
and inlet temperature. Check system logs for temperature
and thermal component failures.

PSU0033

Message

The temperature for power supply <number> is outside of
the allowable range.

Details

System performance may be degraded.

Action

Check the system operating environment, including airflow
and inlet temperature. Check system logs for temperature
and thermal component failures.

PSU0034

Message

An under voltage fault detected on power supply <number>.

Details

This failure may be the result of an electrical issue with
cables or subsystem components in the system.

Action

1.

Remove and reinstall the power supply.

2.

Check cables and subsystem components in the system

for damage.

116